ATEX & IECEx HART Signal Repeater 9106
Model : PR 9106B1A
Brand: PR Electronics
Isolated barrier and HART transparent repeater for harsh and hazardous environments.
24 VDC supply via power rail or connectors
2-wire transmitter input
Active and passive mA input
Active or passive output via the same two terminals
Splitter function – 1 in and 2 out
Loop break and sensor error detection
2.6kVAC galvanic isolation
SIL3 Full Assessment and certified acc. to IEC 61508
Application
- 9106B is a 1- or 2-channel isolated 1:1 repeater barrier for intrinsic safety applications.
- The device supplies 2-wire SMART transmitters and can also be used for 2-wire SMART current sources. HART & BRAIN protocols are supported and are transferred bi-directionally.
- 9106B can be mounted in the safe area or in zone 2 / Cl. 1, div. 2 and receive signals from zone 0, 1, 2 and zone 20, 21, 22 including mining / Class I/II/III, Div. 1, Gr. A-G.
- For duplication/migration purposes, the outputs can be sent to two different DCS/PLC/HMI or any monitoring system.
- In safety applications (SIL loops), the 9106BxBx can be used as a splitter with the following output configuration:
• When using 9106BxBx in a SIL2 safety function, channel 1 is used for the safety loop. Channel 2 can be used for any non-safety device.
• For higher safety purposes (SIL 3), 9106BxBx can be used as a splitter for SIL 3 loops. Channel 1 and 2 are then connected to the same safety PLC, where channel 2 is used as a redundant diagnostic channel (for more information, consult the FMEDA Report and the Safety Manual).
Advanced features
- The PR 45xx detachable display and the green and red front LEDs indicate operation status for each channel.
- Monitoring of error events and cable breakage on input via the individual status relay and/or a collective electronic signal via the power rail.
- Suitable for the use in systems up to Performance Level “d” according to ISO-13849.
Technical characteristics
- High galvanic isolation of 2.6 kVAC.
- Fast response time <5 ms
- High accuracy better than 0.1%.
- 2-wire transmitter supply >16 V.
Mounting
- The devices can be mounted vertically or horizontally without distance between neighboring units.
Source: PR9106B Official Page
Product Documents:
- Datasheet
- User Manual (English)
- User Manual (Russian)
- Safety manual (SIL)
- PR Electronics Isolated Barrier Brochure
- PR Electronics Product Guide
Certifications:
- ATEX certificate
- IECEx certificate
- CCC Certificate
- FM certificate
- INMETRO certificate
- SIL certificate
- UL certificate
- DNV marine certificate
- ClassNK certificate
- EAC declaration
- EAC Ex certificate
- Metrology Pattern Approval (MPA), Russia