E112 Explosion proof


The E112 is a popular model in our range of explosion proof flow rate indicators / transmitters. In addition to the average K-Factor, 15 linearization points can be entered. The unit will interpolate between these points greatly enhancing accuracy in any flow range. The E-series is distinguished by its high-quality manufacturing and its functionality driven European design. We believe, it is not just about fulfilling the requirements for explosion proof, but it is about safety during daily operation.

Share as :
  • Product specifications

    • Signal Inputs

      • Flowmeter Inputs

        • Pulse type inputs:
          Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.
      • Status Inputs

        • Remote control: external input for clearing total or to disable manual clearing by the keypad.
    • Signal Outputs

      • Pulse outputs

        • Function: Scaled pulse output according to linearized accumulated total (e.g. a pulse every 3.25 gallons) and unscaled pulse input retransmission.
          Max. frequency: 500Hz.
          Retransmission: Minimum pulse duration: 50µs, Adjustable pulse length from 1 msec. Up to 10 seconds.
        • Type: One passive NPN transistor and one isolated electro-mechanical relay.
      • Alarm outputs

        • None.
      • Analog outputs

        • Function: Re-transmitting the linearized flow rate – the output can be scaled to any range (e.g. 200 L/min to 1200 L/min).
        • Type: One galvanically isolated, loop powered 4 – 20mA output.
    • Supply

      • Power Supply

        • Long life Lithium battery.
        • 4 – 20mA. Output loop powered.
        • 9 – 27V DC.
      • Sensor Supply

        • 3, 8.2, 12, 24V DC.
    • Hazardous Area

      • Intrinsically Safe

        • For Intrinsically Safe applications we recommend the F-Series.
      • Explosion Proof

        • ATEX:
          Gas: II 2 G Ex db IIC T6 Gb.
          Dust: II 2 D Ex tb IIIC T85°C Db.
        • IECEX:
          Gas: Ex db IIC T6 Gb.
          Dust: Ex tb IIIC T85°C Db.
        • FM and CSA C-US:
          XP (Explosion-proof): Class I, Division 1, Groups A, B, C, D.
          DIP (Dust-Ignition-proof): Class II/III, Div. 1, Groups E, F, & G.
          Gas: Class I, Zone 1, AEx d IIC T6 Gb.
          Dust: Zone 21, AEx tb IIIC T85°C Db.

           

          Remote configuration via free downloadable remote configuration tool (see dropdown download above).

          •  Communication:
            • Type: RS232, RS485 2-wire Modbus RTU or Local USB.
            • Function: Reading display information, clear total, reading / writing all configuration settings and data log extraction.
            • HART communication is available with the E018 Flow rate Monitor / Totalizer.