E119 Explosion proof
The E119 explosion proof totalizer can send a “print receipt” command to a printer. The configurable ticket printing can be set for (daily) totals or delivery tickets. The linearization greatly enhances accuracy in any flow range. The scaled pulse output re-transmits the linearized accumulated total. Daily total and 15 previous day totals can be added to the main display.
-
Product specifications
-
Signal Inputs
-
Flowmeter Inputs
- Pulse type inputs:
Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.
- Pulse type inputs:
-
Status Inputs
- Remote control: two external inputs for clearing total, disable manual clearing, print totalizer ticket, reprint last ticket or end delivery.
-
-
Signal Outputs
-
Pulse outputs
- Function: Scaled pulse output according to linearized accumulated total (e.g. a pulse every 3.25 gallons) and unscaled pulse input retransmission.
Max. frequency: 500Hz.
Retransmission: Minimum pulse duration: 50µs, Adjustable pulse length from 1 msec. Up to 10 seconds. - Type: One passive NPN transistor and one isolated electro-mechanical relay.
- Function: Scaled pulse output according to linearized accumulated total (e.g. a pulse every 3.25 gallons) and unscaled pulse input retransmission.
-
Alarm outputs
- None.
-
Analog outputs
- Function: Re-transmitting the linearized flow rate – the output can be scaled to any range (e.g. 200 L/min to 1200 L/min).
- Type: One galvanically isolated, loop powered 4 – 20mA output.
-
-
Supply
-
Power Supply
- Long life Lithium battery.
- 4 – 20mA. Output loop powered.
- 9 – 27V DC.
-
Sensor Supply
- 3, 8.2, 12, 24V DC.
-
-
Hazardous Area
-
Intrinsically Safe
- For Intrinsically Safe applications we recommend the F-Series.
-
Explosion Proof
- ATEX:
Gas: II 2 G Ex db IIC T6 Gb.
Dust: II 2 D Ex tb IIIC T85°C Db. - IECEX:
Gas: Ex db IIC T6 Gb.
Dust: Ex tb IIIC T85°C Db. - FM and CSA C-US:
XP (Explosion-proof): Class I, Division 1, Groups A, B, C, D.
DIP (Dust-Ignition-proof): Class II/III, Div. 1, Groups E, F, & G.
Gas: Class I, Zone 1, AEx d IIC T6 Gb.
Dust: Zone 21, AEx tb IIIC T85°C Db.
- ATEX:
-
-
Communication:
Function: Configurable communication mode: Ticket printing on demand (delivery), ticket printing of daily totals or at contract hour, read and modify all process data and settings.
Type: RS232 or RS485 2-wire Modbus RTU.
Remote configuration via free downloadable remote configuration tool (see dropdown download above).
HART communication is available with the E018 Flow rate Monitor / Totalizer.
-